ZERO EXPORT EXPLAINED
t up for Zero Export. Even in Off-Grid Mode, there are instances where you could potentially export to the grid when you do not intend to, and this guide is bui.
Both On-grid inverter & Hybrid inverter support Export Control. 3. How Export control Works 1. CT/Meter required. 2. For parallel mode, only need to set on the master inverter 3. Correct setting of the limit value of export control by the inverter l Single phase inverter(Meter/CT solution): Menu main-- settings-- Advanced settings--Export Control
1. CT/Meter required. 2. For parallel mode, only need to set on the master inverter 3. Correct setting of the limit value of export control by the inverter l Single phase inverter(Meter/CT solution): Menu main-- settings-- Advanced settings--Export Control Set Export control power to 0W Single-phase inverter connected to single-phase grid
Note: If there are three-phase microinverters installed at one site, only the Total Limit Mode will be available. The total export power is calculated by subtracting the combined load consumption from the combined PV production. Export power in one phase can compensate for import power in another phase.
In order to get maximum export, change this value until it matches the output rating of the inverter. For example, a 7.6K inverter means that Backflow Power should be “+7600W” and a 10K would be “+10000W”. Step 3: Enabling and disabling the Backflow Power setting